The following is the gas tank.Gas cylinder filling connectorDuring the canning process, there may be problems and some solutions. Customers can troubleshoot and perform some simple repairs on their own. If they still cannot solve the problem, it is recommended to contact GripSeal whether they need to return to the factory for repair.
| fault problem |
The state when a problem occurs | Possible reasons |
The proposed solution |
| Gas leakage at connector and valve connection | Persistent gas overflow sound | Connector'sOType sealing ring damagebad Or the cylinder valve is damaged. |
Check the connector'sOWhether the type sealing ring is damaged and needs to be replaced |
| When the inflation cycle begins Gas leakage, the amount of leakage decreases as pressure increases | The sound of a gas leak | 1Inappropriate connection 2Due to the rigid supply line, the filling connector is subjected to lateral loads |
1Stop the canning cycle and re-establish the connection 2Replace the current supply line with flexible cord |
| Gas leakage increases with pressure | The sound of a gas leak | Valve thread damages seat/Valve threaddamaged |
Stop canning and replace damaged valves |
| Loose safety handle |
Excessive lateral movement of the handle when connected to the valve | Loose or missing screws for safety handle | Remove the existing screws and replace them with new ones |
| The connector handle cannot be fully integrated. | Check if the threads at the connector and valve connections are exposed | Short connection to gas tank valve | Disconnect and reconnect until the connector is fully inserted into the valve |
| Connector minions fail to expand normally when connected | Check the minions of the connector | Connector and valve connections are short | Disconnect and check whether the minions of the connector are damaged or deformed., please contact Gracie to replace the corresponding accessories. |
| loose connection | Although the connection is correct, the connector is still loose | Cylinder valve threads are worn or damaged | Replace cylinder valve |
| The connector body, sleeve, and sleeve threads are damaged, deformed, and may have internal leaks | The connector is difficult to operate. | improper operation | Stop use immediately and contact GripSeal to determine the cause of the problem |
| Unable to connect | Unable to fully actuate connector handle | Valve thimble bending/Damaged brake piston |
Replace valve thimblecontactGripSealAfter-sales return maintenance |