Email: info@gripseal.com -
Tel: +86 0755-86215125 -
Company Address: 4th Floor, Building 30, Chentian Industrial Zone, Xixiang, Bao'an District, Shenzhen
GripSealofficially launchedC70seriesUQDLiquid-cooled connector. The product is based onOCPStandard design, suitable forAIThe liquid-cooled pipeline connection of servers, data centers, and high-density computing power equipment provides an efficient, safe, and leak-free quick connector solution.
Industry-renowned instrument manufacturer customers, their pipeline pressure measuring instrument needs to be tested for quick sealing connection. Some of the instruments are externally threaded interfaces, and there are also flange interfaces made of aluminum alloy. There should be no scratches on the surface of the finished nozzle. In the production process, the sealing and inflation test is done. The traditional method is: the thread is tightened with a wrench, and the flange port is wrapped with a silicone hose and pressed with a clamp. The operation is more cumbersome, and the coordination is inconsistent. It is also prone to leakage misjudgment. It is necessary to consider the use of a special fast sealing connector.
Project introduction:Hydraulic components and valve threaded high pressure quick seal connections Project requirements:Hydraulic components and valves after welding oil pressure or water pressure test, the thread needs to be quickly sealed connection Program advantages:G80HIt is a high-pressure quick-sealing joint for internal threads.G85HIt is a high-pressure quick-sealing joint for external threads, pressure350bar. There is a pressure-assisted grip design inside, which is simple to use. one-second connection, instantaneous sealing, safe and reliable. improve connection efficiency5-10Times.
Project introduction:Automation integrated equipment vendors have a variety of pipe fittings threads that require quick sealing connections Project requirements:Automatic testing of components is a trend, and a large number of pipe fittings and threads require automatic or manual sealing to improve testing efficiency. Program advantages:G10ProIt is an intelligent quick connector for automatic and fast sealing of straight pipes. It has its own magnetic sensor to feedback whether the quick connector is moving. GripSealIt is a comprehensive quick connector solution provider around you, quickly providing a variety of standard or customized quick connectors.
Project introduction:Quick connection of water heater water tank and comprehensive test of the whole machine Project requirements:Large-scale hermetic or comprehensive testing requires quick sealing of threads and nozzles Program advantages:G85VExternal thread series connector, pneumatic operation and can reduce the damage to the thread, reduce the labor intensity of the operator, is currently the optional solution for water heater manufacturers. One-second connection, instantaneous sealing, improve testing efficiency.
Project introduction:Air tightness test after welding of compressor and evaporator condenser requires quick sealing connection of pipe fittings Project requirements:High pressure quick sealing connection of straight pipe or flared pipe, and can pass airtight leak detection. Program advantages:G70KThe series of high-pressure quick connectors for flaring pipes can meet the sealing of the flaring pipes of compressors and two devicesG30/G35Straight pipe quick connector, can meet the high pressure connection of aluminum pipe, copper pipe, low carbon steel, stainless steel pipe, pressure70barOne-second connection, instantaneous sealing, safe and reliable
Project introduction:Auto parts, new energy vehicles, home appliance water heaters, instrumentation, airtight leak detection testing Project requirements:After welding, bonding, and assembly, airtight leak detection tests (water inspection, air pressure leak detection, helium leak detection, etc.) are required to quickly seal and connect various pipe fittings to improve leak detection efficiency. Program advantages:G35The straight pipe quick connector can meet the requirements of quick sealing connections such as cooling water pipes, air conditioning refrigeration copper pipes, aluminum pipes, stainless steel pipes, etc., and can achieve a higher airtightness level to improve the efficiency of leak detection.
GripSealofficially launchedC70seriesUQDLiquid-cooled connector. The product is based onOCPStandard design, suitable forAIThe liquid-cooled pipeline connection of servers, data centers, and high-density computing power equipment provides an efficient, safe, and leak-free quick connector solution.
Industry-renowned instrument manufacturer customers, their pipeline pressure measuring instrument needs to be tested for quick sealing connection. Some of the instruments are externally threaded interfaces, and there are also flange interfaces made of aluminum alloy. There should be no scratches on the surface of the finished nozzle. In the production process, the sealing and inflation test is done. The traditional method is: the thread is tightened with a wrench, and the flange port is wrapped with a silicone hose and pressed with a clamp. The operation is more cumbersome, and the coordination is inconsistent. It is also prone to leakage misjudgment. It is necessary to consider the use of a special fast sealing connector.
Email: info@gripseal.com
Tel: +86 0755-86215125
Company Address: 4th Floor, Building 30, Chentian Industrial Zone, Xixiang, Bao'an District, Shenzhen